Telecom & distributed infrastructure cooling

Keep cooling stable.Use less power.

VENTUS Smart Free Cooling maximizes energy efficiency by minimizing compressor runtime whenever operating conditions allow.

25+years in telecom cooling
9K+units supplied as of May 2026
KT · SKTcertified and deployed

Deployments

Installed across Korea.

Documented VENTUS installations at 143 telecom sites across 16 provinces and metropolitan cities, from Seoul equipment rooms to Jeju base stations.

South Korea

Seoul metro39 sites
×2.4

Hover a marker for site photos

143
Documented sites
16
Provinces & metros
2020–26
Recorded period

Hover a marker

See where VENTUS is installed.

Photos, products and installation dates for each site appear here.

Documented sites only. Not a complete delivery list.

Latest installations

Swipe or use the arrows to browse recent sites.

Applications

High-efficiency cooling for sites that never stop.

From base stations and equipment rooms to edge infrastructure and modernization projects, VENTUS supports continuous 24/7 cooling with lower energy demand.

Configuration view of a VENTUS cooling unit in a telecom equipment room
Equipment room configuration
  1. 01

    Telecom shelters

    Continuous cooling for base stations and remote telecom rooms.

  2. 02

    Exchanges & equipment rooms

    Stable temperatures for thermally sensitive telecom equipment.

  3. 03

    Edge infrastructure

    Compact technical spaces with rapidly changing load and ambient conditions.

  4. 04

    Facility modernization

    Replacement of aging HVAC systems and reduction of cooling power.

Engineered for each site

Configured around your site.

VENTUS can adapt mounting, airflow, equipment layout, and enclosure interfaces for nonstandard installations, including container mounted applications. Final scope is confirmed through engineering review.

MountingAirflowLayoutInterfaces

Example configuration

Container Mounted · Mounting, airflow and interface coordination

Technology

Smart Free CoolingAdaptive control

Smart Free Cooling precisely adjusts operation in real time based on outdoor temperature and cooling load. It is the VENTUS technology that cuts unnecessary compressor runtime and energy use to dramatically reduce annual energy consumption.

Configuration image based on SFC technical drawings.

VENTUS 35.2 kW up-flow indoor cooling unit with open service panels
35.2 kW (10RT) up-flow indoor unit
01

≤46°F (8°C)

Free cooling

At low outdoor temperatures, the system relies primarily on the refrigerant pump to minimize compressor runtime and reduce energy consumption.

02

46–68°F (8–20°C)

Hybrid

The refrigerant pump and compressor work together to reduce unnecessary operation at full output and improve overall system efficiency.

03

>68°F (20°C)

Compressor

At high outdoor temperatures or under heavy thermal loads, the compressor provides the cooling capacity required to maintain stable cooling performance.

35 registered patents in Korea, the U.S., China and Japan, including the cooling apparatus and its control method.

Performance

VENTUS efficiency, shown in measured results.

Efficiency rises as outdoor temperature falls, reaching 88.6 Btu/Wh at 37.4°F and 50% load.

Converted EER by outdoor temperature

At 100% load, efficiency is 4.5× higher at 37.4°F than at 95°F.

Smart Free Cooling turns the compressor off in free cooling mode and draws power only for the refrigerant pump, so it records an EER that cannot be compared with the ratings of compressor-based systems.

CompressorHybridFree cooling0255075100Converted EER, Btu/Wh100°F90°F80°F70°F60°F50°F40°F30°FOutdoor temperature, °FColder →10.915.616.649.013.421.860.288.650% load100% load

95°F · 100% load

10.9Btu/Wh

111,800 Btu/h cooling

10.296 kW input

Compressor active

37.4°F · 100% load

49.0Btu/Wh

108,200 Btu/h cooling

2.207 kW input

Free cooling

37.4°F · 50% load

88.6Btu/Wh

62,100 Btu/h cooling

0.703 kW input

Free cooling

Independent laboratory evaluation

Tested by a CNAS-accredited (ILAC-MRA) laboratory under KT supervision, report no. 202510-RD-001. Outdoor-unit sound held to 69 dBA or less.

Field-representative installation

Full- and partial-load tests run on a refrigerant piping length that reflects field conditions.

Fully automatic operation

Measured with no manual intervention, reflecting real operating behavior.

Estimated annual energy use, Los Angeles

10RT (35.2 kW) unit at a 70.2% annual average load

Test conditionsIndoor ≈81°F dry bulb · Outdoor 95–37.4°F · 100% / 50% load · 98.4 ft (30 m) piping · Values averaged over 35 minutes after stabilization

Conventional inverter-type DX (reference)81,871 kWh

VENTUS Smart Free Cooling37,768 kWh

−54%less annual energy(53.9%)

Estimated, but not a rough guess: the efficiency gap between the two systems is measured.The starting point is the K-HVAC report (AR-25-281, manual mode), measured at an accredited test laboratory, which compares a conventional inverter-type DX unit and VENTUS Smart Free Cooling at 37°F, 54°F and 95°F outdoor temperature and 100% load. That annual comparison was originally run on Korean weather. We kept the measured efficiency difference at each temperature and changed only the weather, using five years of hourly Los Angeles (LAX) temperatures, 2020–2024 (NOAA / NSRDB), with values between test points interpolated. Only the weather is estimated, which is why we call the result an estimate. Same method: San Jose −54%, New York −51%, Washington, DC −50%. Reference: a conventional inverter-type (variable-speed compressor) 10RT DX air conditioner.

Notes

Unit conversion: 1 kW = 3,412 Btu/h; 1 W/W = 3.412 Btu/Wh. Converted values are provided for unit comparison only and are not AHRI 390 certified ratings. Results apply to the tested sample under the stated conditions.

Company

Proven since 1999.

1999Prototype testing with SKT begins
KT · SKTTwo major telecom operators in South Korea
9,316 UnitsCumulative deliveries as of May 2026

From prototype and base-station field trials with SKT to certification by KT and SKT, nationwide deployment, and the continued advancement of Smart Free Cooling, VENTUS brings decades of proven telecom cooling experience.

A track record built in telecom operations

  1. 1999–2002

    Field Validation

    SKT prototype testingThree rounds of base-station field trials2003 certification and pilot deployment

  2. 2003–2018

    Certification & nationwide deployment

    2003–2009 · 3,355 units supplied to SKT2011 · KT certification2012–2018 · Expanded supply to both carriers

  3. 2019–2025

    Smart Free Cooling Advancement

    2018 · Transition to Smart Free Cooling2019 · SFC 1.0 certified by KTSFC 2.0 · KT in 2024 · SKT in 2025

  4. 2026 →

    Next-Generation Transition

    May 2026 · SKT 116 units · KT 66 unitsR-454B applied (2026 target)AI operating platform in active development

Next-generation refrigerant R-454B · Applied (2026 target)

Under the U.S. EPA’s AIM Act rules, refrigerants in new data-center and IT-equipment cooling systems are limited to 700 GWP from January 1, 2027. Ahead of that change, VENTUS set a 2026 target for a wholesale move to a next-generation refrigerant, and the switch to R-454B (GWP about 466, A2L class) is already complete. It is engineered to keep performance comparable to R-410A in the same physical footprint. R-410A models remain available for now.

About the AIM Act: the American Innovation and Manufacturing Act is a U.S. federal law enacted in December 2020. It does two things. First, it phases down the production and import of HFC refrigerants by 85% from the baseline by 2036. Second, under the EPA’s Technology Transitions rule, it sets a global warming potential (GWP) ceiling for refrigerants in new equipment, sector by sector. For data centers, IT-equipment facilities and computer-room cooling, that ceiling is 700 GWP from January 1, 2027. R-410A has a GWP of about 2,088, and R-454B about 466. The rules can be amended, so check the latest EPA notices.

AI-assisted operation · Under active development

VENTUS is actively building AI into Smart Free Cooling. The goal is a system that picks its operating mode by itself from weather and load, and coordinates compressor, fans and valves to use less power for the same cooling. It will trace faults to their root cause, warn before a part needs replacing, recover from minor faults without a technician visit, and keep learning from each site’s own operating data. Every decision is shown with its reasons, and if the AI or communications fail, the system returns to conventional operation so cooling never stops. These are features under development, not released product performance.

Products

Engineered around your site.

Explore cooling capacities, system types, and airflow configurations designed for different installation requirements.

17.6 kW Direct expansion (DX) Up flow VENTUS cooling product

Direct expansion (DX)

17.6 kW5 tons
35.2 kW10 tons
70.4 kW20 tons
200 kW57 tons

Water cooled

70.4 kW20 tons
105.6 kW30 tons

Direct expansion

17.6 kW5 tons

Cooling capacity
17.6 kW / 5 tons
System type
Direct expansion (DX)
Airflow
Up flow

Hover to view products

Contact

Ask us anything.

A product question, a technical doubt, or a site you are still evaluating. Send it in whatever form it comes. A one-line question is enough to start.

Send a quick message

We pass it to the right team and reply within 3 business days.

Product questions and product materials go to our product team. Technical questions and manuals go to customer support. Your details are used only to reply to you. Privacy policy

What is it about?

Or write to the right team directly

Anything else is welcome too. Our customer support team will point you to the right person.